Numerical Control Magnetic Field Generation System

The electromagnetic field control platform is generally divided into electromagnet system and Helmholtz coil system.

It can provide the corresponding frequency and peak magnetic field required by customers.

System Composition:

 

 

Helmholtz coil: An AC magnetic field of a certain frequency can be divided into one, two, and three dimensions.
Power supply: Signal generator + power amplifier, frequency, and waveform are adjustable; Power supply with single waveform (mostly sine wave), frequency adjustable.
Gaussmeter: measuring ac and DC magnetic field intensity, with analog output interface, can be connected to an oscilloscope to observe waveform.
Control software: adjustable ac magnetic field frequency and secondary value, and real-time monitoring of magnetic field changes, magnetic field peak, frequency, and other parameters can be observed.

 

 

Parameters of Helmholtz Coil

 

Model: DXHC25-100
The radius: 250mm
Center magnetic field: 100Gs
Diameter of the uniformity area: 160mm; the degree of uniformity area: 5%
Diameter of the uniformity area: 125mm; the degree of uniformity area: 1%
Diameter of the uniformity area: 40mm; the degree of uniformity area: 0.5%
Approx. weight: 50kg

Model

DXACF-2500

Max. output voltage

50V

Max. output current

50A

Working frequency range

0-1000Hz

Amplitude of input signal

0-±5V

Nonlinear distortion (current)

<0.5%

Output SNR

>76dB

Power input

220VAC±10%

Surrounding temperature

0-40℃

Surrounding humidity

<80%R.H.

Cooling mode

Air cooling

Max.Value Min.Value Peak Value Valley Peak

Automatic Zero, Automatic /manual range

Probe calibration, memory operation mode

Measuring graphic display, curve graphic

RS232/USB connector

Threshold setting (upper limit and lower limit) and alarm

Data saving (automatic /manual) /Reading

Zero setting/ Relative measuring mode

Unit selectable, Gauss, Tesla, A/M or Oe

Range

±100kGs/±10T (common) 6Gs/600uT (weak magnetic probe)

Resolution

0.1uT/1mT (standard), 0.01uT/0.1mT (weak magnetic probe)

Accuracy ( display value)

DC: ±0.20% of reading, ±0.05% of range

AC: ±1% of reading, ±0.5% of range

Frequency range

DC

AC ( Effective value) 0-50kHz

Frequency display range: 1 to 9999Hz

Analog output ( X, Y, Z)

Output voltage: ±3V F.S

Analog connector

BNC ±3V-±3T

Additional influence

Temperature coefficient ±(0.02% ±1 count)℃

Temperature range

Working temperature: 0℃+50℃

Storage temperature: -20℃-+60℃

Communication interface

RS-232/USB/BNC

Panel display

VGA, 320*240 pixel, 3.5-inch colorful screen

Power

220V/50-60Hz

Frequency

Current

Magnetic field strength

0HZ

50A

100GS

10HZ

50A

100GS

50HZ

40A

80GS

1000HZ

2A

4GS

Coil Type

Shape

Coil Equivalent Radius (cm)

Central 

Magnetic Field

(Gs)

Weight(Kg)

(one dimensional)

DXF 150-2

square

150

2

84

DXF 100-10

square

100

10

180

DXF 100-5

square

100

5

94

DXF 100-2

square

100

2

58

DXF 75-10

square

75

10

80

DXF 75-5

square

75

5

53

DXF 75-2

square

75

2

21

DXF 60-10

square

60

10

68

DXF 60-2

square

60

2

14

DXF 50-20

square /circle

50

20

61

DXF50-10

square /circle

50

10

47

DXF 50-2

square /circle

50

2

15

DXF 40-50

square /circle

40

50

98

DXF 40-10

square /circle

40

10

30

DXF 40-2

square /circle

40

2

15

DXHC 30-100

circle

30

100

80

DXHC 30-50

circle

30

50

40

DXHC 30-10

circle

30

10

17

DXHC 30-2

circle

30

2

8

DXHC 25-1000

circle

25

1000

500

DXHC 25-500

circle

25

500

250

DXHC 25-300

circle

25

300

150

DXHC 25-200

circle

25

200

100

DXHC 25-100

circle

25

100

50

DXHC 25-50

circle

25

50

25

DXHC 25-10

circle

25

10

12

DXHC 20-500

circle

20

500

160

DXHC 20-200

circle

20

200

64

DXHC 20-100

circle

20

100

32

DXHC 20-10

circle

20

10

8

DXHC 15-300

circle

15

300

54

DXHC 15-200

circle

15

200

36

DXHC 15-100

circle

15

100

18

DXHC 15-50

circle

15

50

9

DXHC 15-10

circle

15

10

6

DXHC 10-200

circle

10

200

20

DXHC 10-100

circle

10

100

15

DXHC 10-50

circle

10

50

8

DXHC 10-10

circle

10

10

6

The controllable electromagnetic field system can provide the specific AC and DC magnetic fields required by the customer. It is mainly composed of a magnetic field generating device (electromagnet, Helmholtz coil or solenoid, etc.), a programmable Gauss meter, and a power supply.


These devices are connected to the computer through a serial cable and then control the system through PC software in the computer. There are two main methods of control. The first is to directly control the output current of the power supply, thereby controlling the magnitude of the magnetic field strength, and the Gauss meter displays the measured value and Records in the computer for analysis; The second method is to directly set the size of the magnetic field strength through the software. At this time, the power supply will output a stable current until the magnetic field strength reaches the set value and it will stabilize. Both of these two methods provide a set of electromagnetic field systems that can be controlled and form a closed loop of the system.

Device

Product

Instruction

Magnetic Field Generator

Helmholtz coils, electromagnets, solenoids, etc.

Electromagnets are generally used for high magnetic fields, and Helmholtz coils and solenoids are used for uniform low magnetic fields.

Measurement Equipment

Gaussmeter, fluxgate meter, etc.

Generally, use Gaussmeter, but use a fluxgate meter for ultra-low magnetic field (such as 1GS and below)

Power Unit

Programmable Power Supply

Power supplies with different accuracy and stability can be selected according to the requirements of the magnetic field

Control Center

Control Software

Control current output and magnetic field size, and record and analyze it.

Detailed introduction of AC magnetic field control system

Schematic of the magnetic field control system

Components of magnetic field control system

Numerical Control Magnetic Field Generation Systems are usually divided into electromagnet systems and Helmholtz coil systems.

Home > Magnetic Field Source > magnetic field control system Product Introduction

Parameters of power amplifier

Parameters of high-precision gaussmeter

The corresponding value among frequency, magnetic field and current

Other Helmholtz coils option